Customization: | Available |
---|---|
Protection: | Waterproof, Dust-Proof, Insulation |
Feature: | Flat |
Still deciding? Get samples of US$ 2.5/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
For power distribution blocks, the terminal blocks can be bridged with each other using conductor shafts, the corresponding plug-in bridges can be found in the accessories at the bottom.
Working current: 24 A,Operating Voltage: 690 V.
Wiring method: Push-in spring connection.
Rated wiring capacity:2.5mm².
Installation method: NS 35/7.5,NS 35/15.
Product Description | |||||
Product Image | |||||
Product Number | JUT15-4x2.5-P | JUT15-6x2.5-P | JUT15-10x2.5-P | JUT15-12x2.5-P | JUT15-18x2.5-P |
Product Type | Rail wiring distribution block | Rail wiring distribution block | Rail wiring distribution block | Rail wiring distribution block | Rail wiring distribution block |
Mechanical Structure | Push-in spring connection | Push-in spring connection | Push-in spring connection | Push-in spring connection | Push-in spring connection |
Layers | 1 | 1 | 1 | 1 | 1 |
Electric Potential | 1 | 1 | 1 | 1 | 1 |
Connection Volume | 4 | 6 | 10 | 12 | 18 |
Rated Cross Section | 2.5 mm2 | 2.5 mm2 | 2.5mm2 | 2.5mm2 | 2.5mm2 |
Rated Current | 24A | 24A | 24A | 24A | 24A |
Rated Voltage | 690V | 690V | 690V | 690V | 690V |
Open Side Panel | no | no | no | no | no |
Grounding Feet | no | no | no | no | no |
Other | The connecting rail needs to install the rail seat PAD-NS15/35 | The connecting rail needs to install the rail seat PAD-NS15/35 | The connecting rail needs to install the rail seat PAD-NS15/35 | The connecting rail needs to install the rail seat PAD-NS15/35 | The connecting rail needs to install the rail seat PAD-NS15/35 |
Application Field | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial |
Color | gray,dark gray,green,yellow,cream,orange,black,red,blue,white,purple,Brown,customizable | gray,dark gray,green,yellow,cream,orange,black,red,blue,white,purple,Brown,customizable | gray,dark gray,green,yellow,cream,orange,black,red,blue,white,purple,Brown,customizable | gray,dark gray,green,yellow,cream,orange,black,red,blue,white,purple,Brown,customizable | gray,dark gray,green,yellow,cream,orange,black,red,blue,white,purple,Brown,customizable |
Wiring Data | |||||
Line Contact | |||||
Stripping Length | 8mm - 10mm | 8mm - 10mm | 8mm - 10mm | 8mm - 10mm | 8mm - 10mm |
Rigid Conductor Cross Section | 0.14mm² - 4mm² | 0.14mm² - 4mm² | 0.14mm² - 4mm² | 0.14mm² - 4mm² | 0.14mm² - 4mm² |
Flexible Conductor Cross Section | 0.14mm² - 2.5mm² | 0.14mm² - 2.5mm² | 0.14mm² - 2.5mm² | 0.14mm² - 2.5mm² | 0.14mm² - 2.5mm² |
Rigid Conductor Cross Section AWG | 26-12 | 26-12 | 26-12 | 26-12 | 26-12 |
Flexible Conductor Cross Section AWG | 26-14 | 26-14 | 26-14 | 26-14 | 26-14 |
Size(This Is The Size Of The JUT15P Carrying Rail Holder PAD-NS15/35 Installed On The Rail) | |||||
Thickness | 28.8mm | 28.8mm | 28.8mm | 28.8mm | 28.8mm |
Width | 58.5mm | 58.5mm | 58.5mm | 58.5mm | 58.5mm |
High | 21.7mm | 21.7mm | 21.7mm | 21.7mm | 21.7mm |
NS35/7.5 High | 32.5mm | 32.5mm | 32.5mm | 32.5mm | 32.5mm |
NS35/15 High | 40mm | 40mm | 40mm | 40mm | 40mm |
NS15/5.5 High | 30.5mm | 30.5mm | 30.5mm | 30.5mm | 30.5mm |
Material Properties | |||||
Flame Retardant Grade, In Line With UL94 | V0 | V0 | V0 | V0 | V0 |
Insulation Materials | PA | PA | PA | PA | PA |
Insulation Material Group | I | I | I | I | I |
IEC IEC Electrical Parameters | |||||
Standard Test | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 |
Rated Voltage(III/3) | 690V | 690V | 690V | 690V | 690V |
Rated Current(III/3) | 24A | 24A | 24A | 24A | 24A |
Rated Surge Voltage | 8kv | 8kv | 8kv | 8kv | 8kv |
Overvoltage Class | III | III | III | III | III |
Pollution Level | 3 | 3 | 3 | 3 | 3 |
Electrical Performance Test | |||||
Surge Voltage Test Results | Passed the test | Passed the test | Passed the test | Passed the test | Passed the test |
Power Frequency Withstand Voltage Test Results | Passed the test | Passed the test | Passed the test | Passed the test | Passed the test |
Temperature Rise Test Results | Passed the test | Passed the test | Passed the test | Passed the test | Passed the test |
Environmental Conditions | |||||
Ambient Temperature (Operating) | -60 °C - 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C - 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C - 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C - 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C - 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) |
Ambient Temperature (Storage/Transport) | -25 °C - 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C - 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C - 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C - 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C - 60 °C (short term (up to 24 hours), -60 °C to +70 °C) |
Ambient Temperature (Assembled) | -5 °C - 70 °C | -5 °C - 70 °C | -5 °C - 70 °C | -5 °C - 70 °C | -5 °C - 70 °C |
Ambient Temperature (Execution) | -5 °C - 70 °C | -5 °C - 70 °C | -5 °C - 70 °C | -5 °C - 70 °C | -5 °C - 70 °C |
Relative Humidity (Storage/Transportation) | 30 % - 70 % | 30 % - 70 % | 30 % - 70 % | 30 % - 70 % | 30 % - 70 % |
Environmental Friendly | |||||
RoHS | No excessive harmful substances | No excessive harmful substances | No excessive harmful substances | No excessive harmful substances | No excessive harmful substances |
Standards And Specifications | |||||
Connections Are Standard | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 |